Wasp-barcode WLS8600 Product Reference Guide Uživatelský manuál Strana 124

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 144
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 123
WLS8600
5.2 STATUS INDICATORS
The scanner has two indicator LEDs and a Beeper. They signal several operating
conditions, which are described in the tables below.
H = high tone
L = low tone
WLS8600 READER START-UP
Beeper¹
Meaning
L L L L Parameters loaded correctly
H H H H
long tones
Parameter loading error, reading or writing error in the non volatile
memory
H L H L Hardware error in EEPROM
WLS8600 READER CONFIGURATION
Beeper¹
Meaning
H H H H Correct entry or exit from Configuration mode
L Good read of a command
L L L Command read error
WLS8600 READER DATA ENTRY
Beeper¹
LED Good Read Spot Meaning
one beep²
ON ON Correct read of a code in normal mode
H long ON ON Successful advanced format
concatenation
H H H Timeout expired operation not
completed
H H long Error in advanced data formatting
OFF OFF Ready to read a code
¹ Only the Beeper Intensity command can modify these signals.
² The data entry good read tone is user-configurable with all the Beeper commands
in the Reading Parameters section.
118
Zobrazit stránku 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 143 144

Komentáře k této Příručce

Žádné komentáře