Standard Defaults
Product Reference Guide
269
Code 39 Full ASCII
Disable 108
Code 39 Quiet Zones
Auto 109
Code 39 Minimum Reads
2 110
Code 39 Decoding Level
3 111
Code 39 Length Control
Variable 112
Code 39 Set Length 1
2 113
Code 39 Set Length 2
50 114
Code 39 Interdigit Ratio
4 115
Code 39 Character Correlation
Disable 117
Code 39 Stitching
Enable 117
Code 32 (Italian Pharmaceutical Code)
Code 32 Enable/Disable
Disable 118
Code 32 Feature Setting Exceptions
N/A 118
Code 32 Check Char Transmission
Don’t Send 119
Code 32 Start/Stop Character Transmission
Don’t Transmit 119
Code 39 CIP (French Pharmaceutical Code)
Code 39 CIP Enable/Disable
Disable 118
Code 128
Code 128 Enable/Disable
Enable 121
Expand Code 128 to Code 39
Don’t Expand 121
Code 128 Check Character Transmission
Send 122
Code 128 Function Character Transmission
Don’t Send 122
Code 128 Sub-Code Change Transmission
Disable 123
Code 128 Quiet Zones
Auto 124
Code 128 Minimum Reads
1 125
Code 128 Decoding Level
3 126
Code 128 Length Control
Variable 127
Code 128 Set Length 1
1 128
Code 128 Set Length 2
80 129
Code 128 Character Correlation
Disable 130
Code 128 Stitching
Enable 130