Wasp-barcode WDI4600 2D Product Reference Guide Uživatelský manuál Strana 116

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 284
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 115
Enter/Exit Programming Mode Code 39
106
WDI4600
Code 39 Set Length 1
This feature specifies one of the barcode lengths for Code 39 Length Control. Length 1 is the
minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the barcode’s data characters only. The length can be set from 0
to 50
characters.
Table 3 provides examples for setting Length 1. See page 217 for detailed instructions on setting
this feature.
Table 3. Code 39 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC3L1
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
02 = Length 1 is 2 Characters
Zobrazit stránku 115
1 2 ... 111 112 113 114 115 116 117 118 119 120 121 ... 283 284

Komentáře k této Příručce

Žádné komentáře