Wasp-barcode WDI4600 2D Product Reference Guide Uživatelský manuál Strana 165

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 284
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 164
GS1 DataBar™ Expanded Enter/Exit Programming Mode
Product Reference Guide
155
GS1 DataBar™ Expanded Set Length 2
This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control.
Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if
in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be
set from 1 to 74 characters. A setting of 0 specifies to
ignore this length (only one fixed length).
Table 18 provides examples for setting Length 2. See page 217 for detailed instructions on
setting this feature.
Table 18. GS1 DataBar™ Expanded Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (ignore sec-
ond length)
07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CXBL2
Select GS1 DataBar™ Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
74 = Length 2 is 74 Characters
Zobrazit stránku 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 283 284

Komentáře k této Příručce

Žádné komentáře